Reliability Engineering Advisor, Electrical & Power
irenFort Worth, Texas
Posted 9 days agoStill open, checked 2h ago
About the job
Job Type: Full Time | Location: Dallas/Fort Worth | Department: Engineering | Reporting to: Senior Manager, Asset Management| Work Location Type: #hybrid
The role owns the enterprise electrical maintenance and testing strategies and operating limits; assures every maintenance plan meets IEEE, NFPA and NETA; owns the switching, testing and procedure standards the sites execute; leads failure analysis for electrical assets; and defines the OEM versus self-perform split for each electrical asset class. It is hands-on with the site teams: witnessing switching and testing, supporting incidents, conducting readiness reviews at each campus stage, approving fit-for-purpose deviations from Regional Asset Managers, and giving functional direction and mentoring to the site reliability engineers, who execute to its strategies and escalate to it.
With 100% renewable energy, we build, own and operate our data centers and take pride in being at the forefront of sustainable solutions for the ever-evolving applications of high-performance compute. We believe that human progress is invaluable, but it should be done in the right way – responsibly, sustainably and having a positive impact on the communities we operate in.
IREN is a vertically integrated AI Cloud provider, delivering large-scale data centers and GPU clusters for AI training and inference. IREN’s platform is underpinned by its expansive portfolio of grid-connected land and power in renewable-rich regions across North America, Europe and APAC.
The Reliability Engineering Advisor, Electrical & Power is the function's technical authority for IREN's data center electrical infrastructure, from utility and high-voltage intake to the critical load: substations, transformers, switchgear, generators and paralleling, ATS/STS, UPS and batteries, PDU/RPP and busway, protection and controls.The role owns the enterprise electrical maintenance and testing strategies and operating limits; assures every maintenance plan meets IEEE, NFPA and NETA; owns the switching, testing and procedure standards the sites execute; leads failure analysis for electrical assets; and defines the OEM versus self-perform split for each electrical asset class. It is hands-on with the site teams: witnessing switching and testing, supporting incidents, conducting readiness reviews at each campus stage, approving fit-for-purpose deviations from Regional Asset Managers, and giving functional direction and mentoring to the site reliability engineers, who execute to its strategies and escalate to it.
With 100% renewable energy, we build, own and operate our data centers and take pride in being at the forefront of sustainable solutions for the ever-evolving applications of high-performance compute. We believe that human progress is invaluable, but it should be done in the right way – responsibly, sustainably and having a positive impact on the communities we operate in.
- Bachelor's degree in Electrical Engineering or a related discipline; Professional Engineer (PE) licensure, CMRP, CRE or NETA/ETT Level III–IV certification is an asset.
- 10+ years in electrical reliability, maintenance engineering or critical-facilities electrical operations, with demonstrable data center experience across HV, MV and LV systems.
- Deep working knowledge of data center electrical architecture and procedures: utility intake and substations, MV/LV switchgear, transformers, generators and paralleling, ATS/STS, UPS and battery systems, PDU/RPP/busway, protection, grounding and EPMS; N+1 / 2N topologies, maintenance bypass and concurrent maintainability.
- Experience developing and executing switching orders, MOPs/EOPs and energized/de-energized work controls; competent in LOTO and electrical safety under NFPA 70E and OSHA 29 CFR 1910 Subpart S.
- Experience with electrical acceptance and maintenance testing to the ANSI/NETA Acceptance Testing Specifications (ATS) and Maintenance Testing Specifications (MTS), including transformer, breaker, relay, cable and battery testing, thermography and ultrasonic surveys.
- Proven root-cause analysis capability using structured methods (fault tree, event and causal factor charting, Apollo/TapRooT or equivalent, FMEA/FMECA) with the discipline to distinguish failure symptom, mode, mechanism and root cause.
- Working command of the governing standards: NFPA 70 (NEC), NFPA 70B (Electrical Equipment Maintenance), NFPA 70E, NFPA 110/111; IEEE 3007.2, IEEE 493 (Gold Book), IEEE 1584 (arc flash), IEEE C37 and C57 series, IEEE 450/1188/1106 (batteries); ANSI/NETA ATS, MTS and ETT; Uptime Institute Tier and TIA-942 practices; ISO 55001.
- Has built and loaded asset maintenance strategies into a CMMS (Fiix preferred; Maximo, SAP PM) and worked with EPMS and power-quality data; familiar with reliability analytics — MTBF/MTTR, Weibull, Pareto and bad-actor analysis, P-F interval and condition-based strategy design.
- Has written operating limits and defended a maintenance frequency to an OEM and a site lead; has designed or run a self-perform maintenance model against an OEM service agreement, including the responsibility matrix, qualification criteria and warranty-protection conditions.
- Clear, measured communicator able to work with technicians, site engineers, OEMs, NETA firms and executives.
- Pre-employment screening, including background check and substance testing may be required according to company policies.
- Regular travel to the Childress campus and other IREN sites is required; availability to support electrical incidents outside normal hours as needed.