Data Center Electrical Systems & Rack Integration Engineer

OracleUnited States

102.3K–209.5K/yr (customer or client-facing roles may be required to comply with applicable requirements, such as immunization/occupational health mandates, and/or drug testing requirements.Range and benefit information provided in this posting are specific to the stated locations onlyUS: Hiring Range in USD from: $102,300 to $209,500 per annum)

Posted 12 days agoStill open, checked 1h ago

About the job

Job Description

As compute density and power requirements increase, reliable rack-level electrical integration has become a key factor in scaling modern data center infrastructure. This role ensures that new hardware platforms integrate consistently with OCI’s power infrastructure while enabling the telemetry and electrical insight needed to operate large-scale compute environments.

As compute density and power requirements increase, reliable rack-level electrical integration has become a key factor in scaling modern data center infrastructure. This role ensures that new hardware platforms integrate consistently with OCI’s power infrastructure while enabling the telemetry and electrical insight needed to operate large-scale compute environments.

Responsibilities Key ResponsibilitiesRack-Level Electrical Architecture & IntegrationDefine rack-level electrical architectures supporting high-density compute platforms.Translate hardware electrical requirements into deployable rack specifications compatible with OCI data center power infrastructure.Define integration requirements for rack electrical components including power shelves, rPDUs, busbars, cabling, and high-current connectors.Establish rack-level power distribution, redundancy models, and protection boundaries in coordination with data center electrical infrastructure teams.Participate in design reviews with hardware engineering teams to ensure new platforms integrate cleanly into OCI rack standards.Hardware Power Characterization & ValidationDefine and support electrical characterization testing for new IT hardware platforms.Develop testing methodologies to measure power consumption, transient load behavior, and electrical compatibility with rack power infrastructure.Ensure characterization data supports rack design specifications, capacity planning models, and infrastructure planning.Work with lab teams and vendors to validate electrical performance prior to deployment.Electrical Telemetry & Cross-Functional Systems IntegrationDefine requirements for rack-level power telemetry and instrumentation.Partner with software and data engineering teams to ensure telemetry from power shelves, rPDUs, and hardware sensors is accessible and usable at fleet scale.Serve as the electrical domain expert within DCEAM across hardware engineering, facilities engineering, and operations teams.Support development of rack standards and electrical interface specifications that enable consistent global deployments.Required QualificationsBachelor’s or Master’s degree in Electrical Engineering, Power Engineering, or related field.7+ years of experience in electrical engineering related to data center infrastructure, hardware platforms, or high-density power systems.Strong understanding of:rack-level power distribution architectureshigh-current electrical systemspower supply or power shelf architectureselectrical reliability and failure modesExperience working with data center power infrastructure, including familiarity with electrical one-line diagrams, UPS architectures, and transformer-based power distribution.Experience writing technical specifications, requirements, or engineering standards.Ability to translate complex technical requirements into clear engineering specifications and documentation.Preferred QualificationsExperience supporting high-density AI or GPU compute platforms (>40 kW racks).Familiarity with data center power quality metrics, including ITHD and related harmonic or power quality considerations.Experience with AC/DC power supply input stage design or power electronics integration.Familiarity with emerging technologies such as solid-state transformers or advanced power conversion architectures.Understanding of AI training workloads and their impact on power demand patterns at the data center or grid level.Experience working with hardware ODMs, OEMs, or rack integrators.Familiarity with hyperscale rack standards (e.g., ORv3 or Open Compute designs).Responsibilities Key ResponsibilitiesRack-Level Electrical Architecture & IntegrationDefine rack-level electrical architectures supporting high-density compute platforms.Translate hardware electrical requirements into deployable rack specifications compatible with OCI data center power infrastructure.Define integration requirements for rack electrical components including power shelves, rPDUs, busbars, cabling, and high-current connectors.Establish rack-level power distribution, redundancy models, and protection boundaries in coordination with data center electrical infrastructure teams.Participate in design reviews with hardware engineering teams to ensure new platforms integrate cleanly into OCI rack standards.Hardware Power Characterization & ValidationDefine and support electrical characterization testing for new IT hardware platforms.Develop testing methodologies to measure power consumption, transient load behavior, and electrical compatibility with rack power infrastructure.Ensure characterization data supports rack design specifications, capacity planning models, and infrastructure planning.Work with lab teams and vendors to validate electrical performance prior to deployment.Electrical Telemetry & Cross-Functional Systems IntegrationDefine requirements for rack-level power telemetry and instrumentation.Partner with software and data engineering teams to ensure telemetry from power shelves, rPDUs, and hardware sensors is accessible and usable at fleet scale.Serve as the electrical domain expert within DCEAM across hardware engineering, facilities engineering, and operations teams.Support development of rack standards and electrical interface specifications that enable consistent global deployments.Required QualificationsBachelor’s or Master’s degree in Electrical Engineering, Power Engineering, or related field.7+ years of experience in electrical engineering related to data center infrastructure, hardware platforms, or high-density power systems.Strong understanding of:rack-level power distribution architectureshigh-current electrical systemspower supply or power shelf architectureselectrical reliability and failure modesExperience working with data center power infrastructure, including familiarity with electrical one-line diagrams, UPS architectures, and transformer-based power distribution.Experience writing technical specifications, requirements, or engineering standards.Ability to translate complex technical requirements into clear engineering specifications and documentation.Preferred QualificationsExperience supporting high-density AI or GPU compute platforms (>40 kW racks).Familiarity with data center power quality metrics, including ITHD and related harmonic or power quality considerations.Experience with AC/DC power supply input stage design or power electronics integration.Familiarity with emerging technologies such as solid-state transformers or advanced power conversion architectures.Understanding of AI training workloads and their impact on power demand patterns at the data center or grid level.Experience working with hardware ODMs, OEMs, or rack integrators.Familiarity with hyperscale rack standards (e.g., ORv3 or Open Compute designs).Responsibilities Key ResponsibilitiesRack-Level Electrical Architecture & IntegrationDefine rack-level electrical architectures supporting high-density compute platforms.Translate hardware electrical requirements into deployable rack specifications compatible with OCI data center power infrastructure.Define integration requirements for rack electrical components including power shelves, rPDUs, busbars, cabling, and high-current connectors.Establish rack-level power distribution, redundancy models, and protection boundaries in coordination with data center electrical infrastructure teams.Participate in design reviews with hardware engineering teams to ensure new platforms integrate cleanly into OCI rack standards.Hardware Power Characterization & ValidationDefine and support electrical characterization testing for new IT hardware platforms.Develop testing methodologies to measure power consumption, transient load behavior, and electrical compatibility with rack power infrastructure.Ensure characterization data supports rack design specifications, capacity planning models, and infrastructure planning.Work with lab teams and vendors to validate electrical performance prior to deployment.Electrical Telemetry & Cross-Functional Systems IntegrationDefine requirements for rack-level power telemetry and instrumentation.Partner with software and data engineering teams to ensure telemetry from power shelves, rPDUs, and hardware sensors is accessible and usable at fleet scale.Serve as the electrical domain expert within DCEAM across hardware engineering, facilities engineering, and operations teams.Support development of rack standards and electrical interface specifications that enable consistent global deployments.Required QualificationsBachelor’s or Master’s degree in Electrical Engineering, Power Engineering, or related field.7+ years of experience in electrical engineering related to data center infrastructure, hardware platforms, or high-density power systems.Strong understanding of:rack-level power distribution architectureshigh-current electrical systemspower supply or power shelf architectureselectrical reliability and failure modesExperience working with data center power infrastructure, including familiarity with electrical one-line diagrams, UPS architectures, and transformer-based power distribution.Experience writing technical specifications, requirements, or engineering standards.Ability to translate complex technical requirements into clear engineering specifications and documentation.Preferred QualificationsExperience supporting high-density AI or GPU compute platforms (>40 kW racks).Familiarity with data center power quality metrics, including ITHD and related harmonic or power quality considerations.Experience with AC/DC power supply input stage design or power electronics integration.Familiarity with emerging technologies such as solid-state transformers or advanced power conversion architectures.Understanding of AI training workloads and their impact on power demand patterns at the data center or grid level.Experience working with hardware ODMs, OEMs, or rack integrators.Familiarity with hyperscale rack standards (e.g., ORv3 or Open Compute designs).Responsibilities Key ResponsibilitiesRack-Level Electrical Architecture & IntegrationDefine rack-level electrical architectures supporting high-density compute platforms.Translate hardware electrical requirements into deployable rack specifications compatible with OCI data center power infrastructure.Define integration requirements for rack electrical components including power shelves, rPDUs, busbars, cabling, and high-current connectors.Establish rack-level power distribution, redundancy models, and protection boundaries in coordination with data center electrical infrastructure teams.Participate in design reviews with hardware engineering teams to ensure new platforms integrate cleanly into OCI rack standards.Hardware Power Characterization & ValidationDefine and support electrical characterization testing for new IT hardware platforms.Develop testing methodologies to measure power consumption, transient load behavior, and electrical compatibility with rack power infrastructure.Ensure characterization data supports rack design specifications, capacity planning models, and infrastructure planning.Work with lab teams and vendors to validate electrical performance prior to deployment.Electrical Telemetry & Cross-Functional Systems IntegrationDefine requirements for rack-level power telemetry and instrumentation.Partner with software and data engineering teams to ensure telemetry from power shelves, rPDUs, and hardware sensors is accessible and usable at fleet scale.Serve as the electrical domain expert within DCEAM across hardware engineering, facilities engineering, and operations teams.Support development of rack standards and electrical interface specifications that enable consistent global deployments.Required QualificationsBachelor’s or Master’s degree in Electrical Engineering, Power Engineering, or related field.7+ years of experience in electrical engineering related to data center infrastructure, hardware platforms, or high-density power systems.Strong understanding of:rack-level power distribution architectureshigh-current electrical systemspower supply or power shelf architectureselectrical reliability and failure modesExperience working with data center power infrastructure, including familiarity with electrical one-line diagrams, UPS architectures, and transformer-based power distribution.Experience writing technical specifications, requirements, or engineering standards.Ability to translate complex technical requirements into clear engineering specifications and documentation.Preferred QualificationsExperience supporting high-density AI or GPU compute platforms (>40 kW racks).Familiarity with data center power quality metrics, including ITHD and related harmonic or power quality considerations.Experience with AC/DC power supply input stage design or power electronics integration.Familiarity with emerging technologies such as solid-state transformers or advanced power conversion architectures.Understanding of AI training workloads and their impact on power demand patterns at the data center or grid level.Experience working with hardware ODMs, OEMs, or rack integrators.Familiarity with hyperscale rack standards (e.g., ORv3 or Open Compute designs).Responsibilities Key ResponsibilitiesRack-Level Electrical Architecture & IntegrationDefine rack-level electrical architectures supporting high-density compute platforms.Translate hardware electrical requirements into deployable rack specifications compatible with OCI data center power infrastructure.Define integration requirements for rack electrical components including power shelves, rPDUs, busbars, cabling, and high-current connectors.Establish rack-level power distribution, redundancy models, and protection boundaries in coordination with data center electrical infrastructure teams.Participate in design reviews with hardware engineering teams to ensure new platforms integrate cleanly into OCI rack standards.Hardware Power Characterization & ValidationDefine and support electrical characterization testing for new IT hardware platforms.Develop testing methodologies to measure power consumption, transient load behavior, and electrical compatibility with rack power infrastructure.Ensure characterization data supports rack design specifications, capacity planning models, and infrastructure planning.Work with lab teams and vendors to validate electrical performance prior to deployment.Electrical Telemetry & Cross-Functional Systems IntegrationDefine requirements for rack-level power telemetry and instrumentation.Partner with software and data engineering teams to ensure telemetry from power shelves, rPDUs, and hardware sensors is accessible and usable at fleet scale.Serve as the electrical domain expert within DCEAM across hardware engineering, facilities engineering, and operations teams.Support development of rack standards and electrical interface specifications that enable consistent global deployments.Required QualificationsBachelor’s or Master’s degree in Electrical Engineering, Power Engineering, or related field.7+ years of experience in electrical engineering related to data center infrastructure, hardware platforms, or high-density power systems.Strong understanding of:rack-level power distribution architectureshigh-current electrical systemspower supply or power shelf architectureselectrical reliability and failure modesExperience working with data center power infrastructure, including familiarity with electrical one-line diagrams, UPS architectures, and transformer-based power distribution.Experience writing technical specifications, requirements, or engineering standards.Ability to translate complex technical requirements into clear engineering specifications and documentation.Preferred QualificationsExperience supporting high-density AI or GPU compute platforms (>40 kW racks).Familiarity with data center power quality metrics, including ITHD and related harmonic or power quality considerations.Experience with AC/DC power supply input stage design or power electronics integration.Familiarity with emerging technologies such as solid-state transformers or advanced power conversion architectures.Understanding of AI training workloads and their impact on power demand patterns at the data center or grid level.Experience working with hardware ODMs, OEMs, or rack integrators.Familiarity with hyperscale rack standards (e.g., ORv3 or Open Compute designs).Responsibilities Key ResponsibilitiesRack-Level Electrical Architecture & IntegrationDefine rack-level electrical architectures supporting high-density compute platforms.Translate hardware electrical requirements into deployable rack specifications compatible with OCI data center power infrastructure.Define integration requirements for rack electrical components including power shelves, rPDUs, busbars, cabling, and high-current connectors.Establish rack-level power distribution, redundancy models, and protection boundaries in coordination with data center electrical infrastructure teams.Participate in design reviews with hardware engineering teams to ensure new platforms integrate cleanly into OCI rack standards.Hardware Power Characterization & ValidationDefine and support electrical characterization testing for new IT hardware platforms.Develop testing methodologies to measure power consumption, transient load behavior, and electrical compatibility with rack power infrastructure.Ensure characterization data supports rack design specifications, capacity planning models, and infrastructure planning.Work with lab teams and vendors to validate electrical performance prior to deployment.Electrical Telemetry & Cross-Functional Systems IntegrationDefine requirements for rack-level power telemetry and instrumentation.Partner with software and data engineering teams to ensure telemetry from power shelves, rPDUs, and hardware sensors is accessible and usable at fleet scale.Serve as the electrical domain expert within DCEAM across hardware engineering, facilities engineering, and operations teams.Support development of rack standards and electrical interface specifications that enable consistent global deployments.Required QualificationsBachelor’s or Master’s degree in Electrical Engineering, Power Engineering, or related field.7+ years of experience in electrical engineering related to data center infrastructure, hardware platforms, or high-density power systems.Strong understanding of:rack-level power distribution architectureshigh-current electrical systemspower supply or power shelf architectureselectrical reliability and failure modesExperience working with data center power infrastructure, including familiarity with electrical one-line diagrams, UPS architectures, and transformer-based power distribution.Experience writing technical specifications, requirements, or engineering standards.Ability to translate complex technical requirements into clear engineering specifications and documentation.Preferred QualificationsExperience supporting high-density AI or GPU compute platforms (>40 kW racks).Familiarity with data center power quality metrics, including ITHD and related harmonic or power quality considerations.Experience with AC/DC power supply input stage design or power electronics integration.Familiarity with emerging technologies such as solid-state transformers or advanced power conversion architectures.Understanding of AI training workloads and their impact on power demand patterns at the data center or grid level.Experience working with hardware ODMs, OEMs, or rack integrators.Familiarity with hyperscale rack standards (e.g., ORv3 or Open Compute designs).

Responsibilities

Key ResponsibilitiesRack-Level Electrical Architecture & IntegrationDefine rack-level electrical architectures supporting high-density compute platforms.Translate hardware electrical requirements into deployable rack specifications compatible with OCI data center power infrastructure.Define integration requirements for rack electrical components including power shelves, rPDUs, busbars, cabling, and high-current connectors.Establish rack-level power distribution, redundancy models, and protection boundaries in coordination with data center electrical infrastructure teams.Participate in design reviews with hardware engineering teams to ensure new platforms integrate cleanly into OCI rack standards.Hardware Power Characterization & ValidationDefine and support electrical characterization testing for new IT hardware platforms.Develop testing methodologies to measure power consumption, transient load behavior, and electrical compatibility with rack power infrastructure.Ensure characterization data supports rack design specifications, capacity planning models, and infrastructure planning.Work with lab teams and vendors to validate electrical performance prior to deployment.Electrical Telemetry & Cross-Functional Systems IntegrationDefine requirements for rack-level power telemetry and instrumentation.Partner with software and data engineering teams to ensure telemetry from power shelves, rPDUs, and hardware sensors is accessible and usable at fleet scale.Serve as the electrical domain expert within DCEAM across hardware engineering, facilities engineering, and operations teams.Support development of rack standards and electrical interface specifications that enable consistent global deployments.Required QualificationsBachelor’s or Master’s degree in Electrical Engineering, Power Engineering, or related field.7+ years of experience in electrical engineering related to data center infrastructure, hardware platforms, or high-density power systems.Strong understanding of:rack-level power distribution architectureshigh-current electrical systemspower supply or power shelf architectureselectrical reliability and failure modesExperience working with data center power infrastructure, including familiarity with electrical one-line diagrams, UPS architectures, and transformer-based power distribution.Experience writing technical specifications, requirements, or engineering standards.Ability to translate complex technical requirements into clear engineering specifications and documentation.Preferred QualificationsExperience supporting high-density AI or GPU compute platforms (>40 kW racks).Familiarity with data center power quality metrics, including ITHD and related harmonic or power quality considerations.Experience with AC/DC power supply input stage design or power electronics integration.Familiarity with emerging technologies such as solid-state transformers or advanced power conversion architectures.Understanding of AI training workloads and their impact on power demand patterns at the data center or grid level.Experience working with hardware ODMs, OEMs, or rack integrators.Familiarity with hyperscale rack standards (e.g., ORv3 or Open Compute designs).Key ResponsibilitiesRack-Level Electrical Architecture & IntegrationDefine rack-level electrical architectures supporting high-density compute platforms.Translate hardware electrical requirements into deployable rack specifications compatible with OCI data center power infrastructure.Define integration requirements for rack electrical components including power shelves, rPDUs, busbars, cabling, and high-current connectors.Establish rack-level power distribution, redundancy models, and protection boundaries in coordination with data center electrical infrastructure teams.Participate in design reviews with hardware engineering teams to ensure new platforms integrate cleanly into OCI rack standards.Hardware Power Characterization & ValidationDefine and support electrical characterization testing for new IT hardware platforms.Develop testing methodologies to measure power consumption, transient load behavior, and electrical compatibility with rack power infrastructure.Ensure characterization data supports rack design specifications, capacity planning models, and infrastructure planning.Work with lab teams and vendors to validate electrical performance prior to deployment.Electrical Telemetry & Cross-Functional Systems IntegrationDefine requirements for rack-level power telemetry and instrumentation.Partner with software and data engineering teams to ensure telemetry from power shelves, rPDUs, and hardware sensors is accessible and usable at fleet scale.Serve as the electrical domain expert within DCEAM across hardware engineering, facilities engineering, and operations teams.Support development of rack standards and electrical interface specifications that enable consistent global deployments.Required QualificationsBachelor’s or Master’s degree in Electrical Engineering, Power Engineering, or related field.7+ years of experience in electrical engineering related to data center infrastructure, hardware platforms, or high-density power systems.Strong understanding of:rack-level power distribution architectureshigh-current electrical systemspower supply or power shelf architectureselectrical reliability and failure modesExperience working with data center power infrastructure, including familiarity with electrical one-line diagrams, UPS architectures, and transformer-based power distribution.Experience writing technical specifications, requirements, or engineering standards.Ability to translate complex technical requirements into clear engineering specifications and documentation.Preferred QualificationsExperience supporting high-density AI or GPU compute platforms (>40 kW racks).Familiarity with data center power quality metrics, including ITHD and related harmonic or power quality considerations.Experience with AC/DC power supply input stage design or power electronics integration.Familiarity with emerging technologies such as solid-state transformers or advanced power conversion architectures.Understanding of AI training workloads and their impact on power demand patterns at the data center or grid level.Experience working with hardware ODMs, OEMs, or rack integrators.Familiarity with hyperscale rack standards (e.g., ORv3 or Open Compute designs).

Key Responsibilities

Key Responsibilities

Rack-Level Electrical Architecture & Integration

Rack-Level Electrical Architecture & Integration
  • Define rack-level electrical architectures supporting high-density compute platforms.
  • Translate hardware electrical requirements into deployable rack specifications compatible with OCI data center power infrastructure.
deployable rack specifications
  • Define integration requirements for rack electrical components including power shelves, rPDUs, busbars, cabling, and high-current connectors.
power shelves, rPDUs, busbars, cabling, and high-current connectors
  • Establish rack-level power distribution, redundancy models, and protection boundaries in coordination with data center electrical infrastructure teams.
power distribution, redundancy models, and protection boundaries
  • Participate in design reviews with hardware engineering teams to ensure new platforms integrate cleanly into OCI rack standards.

Hardware Power Characterization & Validation

Hardware Power Characterization & Validation
  • Define and support electrical characterization testing for new IT hardware platforms.
electrical characterization testing
  • Develop testing methodologies to measure power consumption, transient load behavior, and electrical compatibility with rack power infrastructure.
  • Ensure characterization data supports rack design specifications, capacity planning models, and infrastructure planning.
  • Work with lab teams and vendors to validate electrical performance prior to deployment.

Electrical Telemetry & Cross-Functional Systems Integration

Electrical Telemetry & Cross-Functional Systems Integration
  • Define requirements for rack-level power telemetry and instrumentation.
rack-level power telemetry and instrumentation
  • Partner with software and data engineering teams to ensure telemetry from power shelves, rPDUs, and hardware sensors is accessible and usable at fleet scale.
  • Serve as the electrical domain expert within DCEAM across hardware engineering, facilities engineering, and operations teams.
electrical domain expert
  • Support development of rack standards and electrical interface specifications that enable consistent global deployments.

Required Qualifications

Required Qualifications
  • Bachelor’s or Master’s degree in Electrical Engineering, Power Engineering, or related field.
Electrical Engineering
  • 7+ years of experience in electrical engineering related to data center infrastructure, hardware platforms, or high-density power systems.
data center infrastructure, hardware platforms, or high-density power systems
  • Strong understanding of:rack-level power distribution architectureshigh-current electrical systemspower supply or power shelf architectureselectrical reliability and failure modes
  • rack-level power distribution architectures
  • high-current electrical systems
  • power supply or power shelf architectures
  • electrical reliability and failure modes
  • Experience working with data center power infrastructure, including familiarity with electrical one-line diagrams, UPS architectures, and transformer-based power distribution.
data center power infrastructure
  • Experience writing technical specifications, requirements, or engineering standards.
technical specifications, requirements, or engineering standards
  • Ability to translate complex technical requirements into clear engineering specifications and documentation.
clear engineering specifications and documentation

Preferred Qualifications

Preferred Qualifications
  • Experience supporting high-density AI or GPU compute platforms (>40 kW racks).
high-density AI or GPU compute platforms (>40 kW racks)
  • Familiarity with data center power quality metrics, including ITHD and related harmonic or power quality considerations.
data center power quality metrics
  • Experience with AC/DC power supply input stage design or power electronics integration.
AC/DC power supply input stage design
  • Familiarity with emerging technologies such as solid-state transformers or advanced power conversion architectures.
solid-state transformers or advanced power conversion architectures
  • Understanding of AI training workloads and their impact on power demand patterns at the data center or grid level.
AI training workloads and their impact on power demand patterns at the data center or grid level
  • Experience working with hardware ODMs, OEMs, or rack integrators.
  • Familiarity with hyperscale rack standards (e.g., ORv3 or Open Compute designs).
Qualifications Disclaimer:Certain U.S. based or U.S. customer or client-facing roles may be required to comply with applicable requirements, such as immunization/occupational health mandates, and/or drug testing requirements.Range and benefit information provided in this posting are specific to the stated locations onlyUS: Hiring Range in USD from: $102,300 to $209,500 per annum. May be eligible for bonus and equity.Oracle maintains broad salary ranges for its roles in order to account for variations in knowledge, skills, experience, market conditions and locations, as well as reflect Oracle's differing products, industries and lines of business.Candidates are typically placed into the range based on the preceding factors as well as internal peer equity.Oracle US offers a comprehensive benefits package which includes the following:1. Medical, dental, and vision insurance, including expert medical opinion2. Short term disability and long term disability3. Life insurance and AD&D4. Supplemental life insurance (Employee/Spouse/Child)5. Health care and dependent care Flexible Spending Accounts6. Pre-tax commuter and parking benefits7. 401(k) Savings and Investment Plan with company match8. Paid time off: Flexible Vacation is provided to all eligible employees assigned to a salaried (non-overtime eligible) position. Accrued Vacation is provided to all other employees eligible for vacation benefits. For employees working at least 35 hours per week, the vacation accrual rate is 13 days annually for the first three years of employment and 18 days annually for subsequent years of employment. Vacation accrual is prorated for employees working between 20 and 34 hours per week. Employees working fewer than 20 hours per week are not eligible for vacation.9. 11 paid holidays10. Paid sick leave: 72 hours of paid sick leave upon date of hire. Refreshes each calendar year. Unused balance will carry over each year up to a maximum cap of 112 hours.11. Paid parental leave12. Adoption assistance13. Employee Stock Purchase Plan14. Financial planning and group legal15. Voluntary benefits including auto, homeowner and pet insuranceThe role will generally accept applications for at least three calendar days from the posting date or as long as the job remains posted.Career Level - IC4Qualifications Disclaimer:Certain U.S. based or U.S. customer or client-facing roles may be required to comply with applicable requirements, such as immunization/occupational health mandates, and/or drug testing requirements.Range and benefit information provided in this posting are specific to the stated locations onlyUS: Hiring Range in USD from: $102,300 to $209,500 per annum. May be eligible for bonus and equity.Oracle maintains broad salary ranges for its roles in order to account for variations in knowledge, skills, experience, market conditions and locations, as well as reflect Oracle's differing products, industries and lines of business.Candidates are typically placed into the range based on the preceding factors as well as internal peer equity.Oracle US offers a comprehensive benefits package which includes the following:1. Medical, dental, and vision insurance, including expert medical opinion2. Short term disability and long term disability3. Life insurance and AD&D4. Supplemental life insurance (Employee/Spouse/Child)5. Health care and dependent care Flexible Spending Accounts6. Pre-tax commuter and parking benefits7. 401(k) Savings and Investment Plan with company match8. Paid time off: Flexible Vacation is provided to all eligible employees assigned to a salaried (non-overtime eligible) position. Accrued Vacation is provided to all other employees eligible for vacation benefits. For employees working at least 35 hours per week, the vacation accrual rate is 13 days annually for the first three years of employment and 18 days annually for subsequent years of employment. Vacation accrual is prorated for employees working between 20 and 34 hours per week. Employees working fewer than 20 hours per week are not eligible for vacation.9. 11 paid holidays10. Paid sick leave: 72 hours of paid sick leave upon date of hire. Refreshes each calendar year. Unused balance will carry over each year up to a maximum cap of 112 hours.11. Paid parental leave12. Adoption assistance13. Employee Stock Purchase Plan14. Financial planning and group legal15. Voluntary benefits including auto, homeowner and pet insuranceThe role will generally accept applications for at least three calendar days from the posting date or as long as the job remains posted.Career Level - IC4Qualifications Disclaimer:Certain U.S. based or U.S. customer or client-facing roles may be required to comply with applicable requirements, such as immunization/occupational health mandates, and/or drug testing requirements.Range and benefit information provided in this posting are specific to the stated locations onlyUS: Hiring Range in USD from: $102,300 to $209,500 per annum. May be eligible for bonus and equity.Oracle maintains broad salary ranges for its roles in order to account for variations in knowledge, skills, experience, market conditions and locations, as well as reflect Oracle's differing products, industries and lines of business.Candidates are typically placed into the range based on the preceding factors as well as internal peer equity.Oracle US offers a comprehensive benefits package which includes the following:1. Medical, dental, and vision insurance, including expert medical opinion2. Short term disability and long term disability3. Life insurance and AD&D4. Supplemental life insurance (Employee/Spouse/Child)5. Health care and dependent care Flexible Spending Accounts6. Pre-tax commuter and parking benefits7. 401(k) Savings and Investment Plan with company match8. Paid time off: Flexible Vacation is provided to all eligible employees assigned to a salaried (non-overtime eligible) position. Accrued Vacation is provided to all other employees eligible for vacation benefits. For employees working at least 35 hours per week, the vacation accrual rate is 13 days annually for the first three years of employment and 18 days annually for subsequent years of employment. Vacation accrual is prorated for employees working between 20 and 34 hours per week. Employees working fewer than 20 hours per week are not eligible for vacation.9. 11 paid holidays10. Paid sick leave: 72 hours of paid sick leave upon date of hire. Refreshes each calendar year. Unused balance will carry over each year up to a maximum cap of 112 hours.11. Paid parental leave12. Adoption assistance13. Employee Stock Purchase Plan14. Financial planning and group legal15. Voluntary benefits including auto, homeowner and pet insuranceThe role will generally accept applications for at least three calendar days from the posting date or as long as the job remains posted.Career Level - IC4Qualifications Disclaimer:Certain U.S. based or U.S. customer or client-facing roles may be required to comply with applicable requirements, such as immunization/occupational health mandates, and/or drug testing requirements.Range and benefit information provided in this posting are specific to the stated locations onlyUS: Hiring Range in USD from: $102,300 to $209,500 per annum. May be eligible for bonus and equity.Oracle maintains broad salary ranges for its roles in order to account for variations in knowledge, skills, experience, market conditions and locations, as well as reflect Oracle's differing products, industries and lines of business.Candidates are typically placed into the range based on the preceding factors as well as internal peer equity.Oracle US offers a comprehensive benefits package which includes the following:1. Medical, dental, and vision insurance, including expert medical opinion2. Short term disability and long term disability3. Life insurance and AD&D4. Supplemental life insurance (Employee/Spouse/Child)5. Health care and dependent care Flexible Spending Accounts6. Pre-tax commuter and parking benefits7. 401(k) Savings and Investment Plan with company match8. Paid time off: Flexible Vacation is provided to all eligible employees assigned to a salaried (non-overtime eligible) position. Accrued Vacation is provided to all other employees eligible for vacation benefits. For employees working at least 35 hours per week, the vacation accrual rate is 13 days annually for the first three years of employment and 18 days annually for subsequent years of employment. Vacation accrual is prorated for employees working between 20 and 34 hours per week. Employees working fewer than 20 hours per week are not eligible for vacation.9. 11 paid holidays10. Paid sick leave: 72 hours of paid sick leave upon date of hire. Refreshes each calendar year. Unused balance will carry over each year up to a maximum cap of 112 hours.11. Paid parental leave12. Adoption assistance13. Employee Stock Purchase Plan14. Financial planning and group legal15. Voluntary benefits including auto, homeowner and pet insuranceThe role will generally accept applications for at least three calendar days from the posting date or as long as the job remains posted.Career Level - IC4Qualifications Disclaimer:Certain U.S. based or U.S. customer or client-facing roles may be required to comply with applicable requirements, such as immunization/occupational health mandates, and/or drug testing requirements.Range and benefit information provided in this posting are specific to the stated locations onlyUS: Hiring Range in USD from: $102,300 to $209,500 per annum. May be eligible for bonus and equity.Oracle maintains broad salary ranges for its roles in order to account for variations in knowledge, skills, experience, market conditions and locations, as well as reflect Oracle's differing products, industries and lines of business.Candidates are typically placed into the range based on the preceding factors as well as internal peer equity.Oracle US offers a comprehensive benefits package which includes the following:1. Medical, dental, and vision insurance, including expert medical opinion2. Short term disability and long term disability3. Life insurance and AD&D4. Supplemental life insurance (Employee/Spouse/Child)5. Health care and dependent care Flexible Spending Accounts6. Pre-tax commuter and parking benefits7. 401(k) Savings and Investment Plan with company match8. Paid time off: Flexible Vacation is provided to all eligible employees assigned to a salaried (non-overtime eligible) position. Accrued Vacation is provided to all other employees eligible for vacation benefits. For employees working at least 35 hours per week, the vacation accrual rate is 13 days annually for the first three years of employment and 18 days annually for subsequent years of employment. Vacation accrual is prorated for employees working between 20 and 34 hours per week. Employees working fewer than 20 hours per week are not eligible for vacation.9. 11 paid holidays10. Paid sick leave: 72 hours of paid sick leave upon date of hire. Refreshes each calendar year. Unused balance will carry over each year up to a maximum cap of 112 hours.11. Paid parental leave12. Adoption assistance13. Employee Stock Purchase Plan14. Financial planning and group legal15. Voluntary benefits including auto, homeowner and pet insuranceThe role will generally accept applications for at least three calendar days from the posting date or as long as the job remains posted.Career Level - IC4Qualifications Disclaimer:Certain U.S. based or U.S. customer or client-facing roles may be required to comply with applicable requirements, such as immunization/occupational health mandates, and/or drug testing requirements.Range and benefit information provided in this posting are specific to the stated locations onlyUS: Hiring Range in USD from: $102,300 to $209,500 per annum. May be eligible for bonus and equity.Oracle maintains broad salary ranges for its roles in order to account for variations in knowledge, skills, experience, market conditions and locations, as well as reflect Oracle's differing products, industries and lines of business.Candidates are typically placed into the range based on the preceding factors as well as internal peer equity.Oracle US offers a comprehensive benefits package which includes the following:1. Medical, dental, and vision insurance, including expert medical opinion2. Short term disability and long term disability3. Life insurance and AD&D4. Supplemental life insurance (Employee/Spouse/Child)5. Health care and dependent care Flexible Spending Accounts6. Pre-tax commuter and parking benefits7. 401(k) Savings and Investment Plan with company match8. Paid time off: Flexible Vacation is provided to all eligible employees assigned to a salaried (non-overtime eligible) position. Accrued Vacation is provided to all other employees eligible for vacation benefits. For employees working at least 35 hours per week, the vacation accrual rate is 13 days annually for the first three years of employment and 18 days annually for subsequent years of employment. Vacation accrual is prorated for employees working between 20 and 34 hours per week. Employees working fewer than 20 hours per week are not eligible for vacation.9. 11 paid holidays10. Paid sick leave: 72 hours of paid sick leave upon date of hire. Refreshes each calendar year. Unused balance will carry over each year up to a maximum cap of 112 hours.11. Paid parental leave12. Adoption assistance13. Employee Stock Purchase Plan14. Financial planning and group legal15. Voluntary benefits including auto, homeowner and pet insuranceThe role will generally accept applications for at least three calendar days from the posting date or as long as the job remains posted.Career Level - IC4

Qualifications

Disclaimer:Certain U.S. based or U.S. customer or client-facing roles may be required to comply with applicable requirements, such as immunization/occupational health mandates, and/or drug testing requirements.Range and benefit information provided in this posting are specific to the stated locations onlyUS: Hiring Range in USD from: $102,300 to $209,500 per annum. May be eligible for bonus and equity.Oracle maintains broad salary ranges for its roles in order to account for variations in knowledge, skills, experience, market conditions and locations, as well as reflect Oracle's differing products, industries and lines of business.Candidates are typically placed into the range based on the preceding factors as well as internal peer equity.Oracle US offers a comprehensive benefits package which includes the following:1. Medical, dental, and vision insurance, including expert medical opinion2. Short term disability and long term disability3. Life insurance and AD&D4. Supplemental life insurance (Employee/Spouse/Child)5. Health care and dependent care Flexible Spending Accounts6. Pre-tax commuter and parking benefits7. 401(k) Savings and Investment Plan with company match8. Paid time off: Flexible Vacation is provided to all eligible employees assigned to a salaried (non-overtime eligible) position. Accrued Vacation is provided to all other employees eligible for vacation benefits. For employees working at least 35 hours per week, the vacation accrual rate is 13 days annually for the first three years of employment and 18 days annually for subsequent years of employment. Vacation accrual is prorated for employees working between 20 and 34 hours per week. Employees working fewer than 20 hours per week are not eligible for vacation.9. 11 paid holidays10. Paid sick leave: 72 hours of paid sick leave upon date of hire. Refreshes each calendar year. Unused balance will carry over each year up to a maximum cap of 112 hours.11. Paid parental leave12. Adoption assistance13. Employee Stock Purchase Plan14. Financial planning and group legal15. Voluntary benefits including auto, homeowner and pet insuranceThe role will generally accept applications for at least three calendar days from the posting date or as long as the job remains posted.Career Level - IC4Certain U.S. based or U.S. customer or client-facing roles may be required to comply with applicable requirements, such as immunization/occupational health mandates, and/or drug testing requirements.Range and benefit information provided in this posting are specific to the stated locations only

Career Level - IC4